Ta-60V Vet Anesthesia Equipment Portable Medical Animal Veterinary Anesthesia Machine with Trolley Cart with Bain Module

Still deciding? Get samples of $ !
Request Sample

Product Description

Basic Information
Model NO.
TA-60V
Transport Package
Wooden Case
Specification
1220x700x1830cm
Origin
China
Capacity
50000PCS/Year
Product Pictures
Product Description

TA60V is a high-end anesthesia machine used in animal hospitals. The design of the product adheres to the concept of anesthesiologists-oriented, completely abandoning the design idea of traditional animal anesthesia machines that only considers product costs.

Through the innovation of product structure and circuit module design, all the gauges and main operating elements of TA60V are arranged on the front of the product to facilitate the operation and observation, and also realize a variety of installations and applications such as wall-mounted, desktop and stand for one model.

Technical Specifications
Ventilation modesIPPV; A/C; SIMV;
Flow meterO2 (0-5L/min)
Rapid oxygen supply35L/min-75L/min
Tidal volume (Vt)0, 20 mL ~ 1500 mL
Frequency (Freq)1bpm ~ 100 bpm
I/E Ratio2:1 ~ 1:6
Pressure triggering sensitivity-20 cmH2O ~ 0 cmH2O
Flow trigger sensitivity0.5 L/min ~ 30 L/min
SIGH0(off) 1/100 ~ 5/100
Apnea VentilationOFF, 5 s ~ 60 s
Pressure Limit20 cmH2O ~ 100 cmH2O
Monitored ParametersFreq, Vt, MV
Graphical displayP-T (pressure - time), F-T (flow - time)
Gas sourceO2 (280kPa-600kPa)
Voltage100-240V, 50/60Hz
Detailed Views
Package & Application
Certificates & Factory
Exhibition & Feedback
Related Products
Frequently Asked Questions
What ventilation modes does the TA-60V support?
The TA-60V supports multiple ventilation modes including IPPV, A/C, and SIMV to cater to different clinical needs in animal hospitals.
Can this anesthesia machine be installed in different ways?
Yes, the innovative design allows for wall-mounted, desktop, and stand-based installations for the same model, providing maximum flexibility.
What is the tidal volume range for this equipment?
The machine offers a wide tidal volume range from 20 mL up to 1500 mL, making it suitable for various animal sizes.
What safety alarms are integrated into the system?
It includes alarms for AC power failure, low battery voltage, no tidal volume, oxygen concentration limits, airway pressure issues, and suffocation warnings.
What are the power and gas requirements?
The machine operates on a voltage of 100-240V (50/60Hz) and requires an O2 gas source with a pressure range of 280kPa to 600kPa.

Related Products